News

Home > News > Content
Fan Coil Unit Status Of Service
Jul 20, 2017

Fan Coil Unit Status of service

Fan coil system is usually the site of the project and the coil connected to the pipeline part of the valve, filters and hoses and other special-shaped pipe, insulation is not simple and dense, and usually protect the often open, it is simple to form a condensate drip, engineering practice , Can be used to return part of the pipeline to the side of the coil side of the way to avoid and make up.

    Condensate drain poor performance of the fan coil coil condensate water to the water outside the overflow, in the air conditioning system running the use of part of the excessive force or hanger failure, the simple formation of slope changes or part of the water, the simple formation Condensate water overflow, which requires strict control of the device in the water pipe slope, and clear the drainage pipe and control the reasonable distance with other pipes. Do not rely on too close to prevent accidental deformation. And check the fixed hanger of the device fixed point to avoid deformation and fall off. In the construction process, some people think that as long as the highest point from the condensate pipe network water, the lowest point can be water, but only water is not enough, but also to ensure that the same amount of water into the line. Otherwise there is part of the water doubt, fan coil air conditioning these local also simple accumulation of impurities and breeding bacteria moss, long-term simple obstruction pipeline. This question must be strengthened construction work, in the condensate pipe insulation is difficult to find and deal with.

    The fan coil is usually installed directly in the air-conditioned room, and its service status and quality of service will affect the indoor noise level of the air quality. Therefore, it is necessary to do the air filter, drip tray, coil, fan and other primary parts of the maintenance of maintenance services to ensure that the fan coil to play a normal role, no negative impact.

    The coil is responsible for the main task of passing hot and cold water to the air through the fan coil. In order to ensure efficient heat transfer, it is necessary to keep the appearance of the coil as bright as possible. However, because the fan coil is usually equipped with coarse filter, the hole is relatively large, in the beginning of the use, can not help but dust through the filter and attached to the coil pipe or fin appearance. If not timely cleaning, it will make the coil in the hot and cold water and the flow of air between the coil to reduce the amount of heat exchange, so that the coil heat transfer efficiency can not be enough to play out. If there are many dust attached, and even some of the air between the fins are blocked, then together will reduce the fan coil air volume, so that further decline in air conditioning function.

    The cleaning method can be carried out with reference to the cleaning method of the air filter, but the cleaning cycle can be longer and usually one year clean. If it is seasonal use of air conditioning, air conditioning in the use of the season after cleaning time. Less than a last resort, do not choose the whole from the installation site to open down the cleaning method to reduce the cleaning workload and disassembly services caused by the impact.

    Fan coil with a period of time, the fins and impeller will accumulate dust and bacteria, when the dust reaches a certain thickness, the fins will be affected by the heat, resulting in the room temperature can not meet the request, the other for a long time is not clean Of the fan coil will breed a variety of bacteria, these bacteria can cause the body's respiratory disease, it is recommended fan coil should be regularly cleaned.

    With the improvement of the air environment requirements, fan coil, fan, heat exchanger and other fresh air unit device has been used by everyone's positive attention. In order to ensure the normal function of the device, here to remind you to do a good job in dust clean up work.

    The coil is responsible for the important task of passing hot and cold water to the air through the fan coil. In order to ensure high efficiency heat transfer, the surface of the coil must be kept as clean as possible. However, since the fan coil is generally equipped with coarse filter, the hole is relatively large, in the beginning of the use, it is inevitable that dust through the filter and attached to the coil of the pipe or rib surface. If not timely cleaning, it will make the coil hot and cold water and the coil outside the flow of heat between the amount of heat to reduce the coil heat transfer efficiency can not be fully brought out. If a lot of dust is attached, even if some of the air channels between the fins are blocked, the air volume of the fan coil will be reduced and the air conditioning performance will be further reduced.





Copyright © Shenyang Jinchen Weiye Cooling & Heating Equipment Co.,Ltd All Rights Reserved.Tel: +86-24-83970918